Rated load(kg): 50-2500
Main features: The product is made of alloy aluminum. It is hermetically sealed with glue to IP65, surface anodized and anti-corrosion, integral structure and easy installation. The product is suit for electronic top scale, floor scale and other weighing equipment.
Parameters: | Precision : C2 |
| Temp. effect on span(%F.S/10deg C): ±0.02 | Comprehensive error(%F.S) : ±0.02 |
| Temp. effect on zero(%F.S/10deg C) : ±0.03 | Rated output(mv/v) : 2.0±0.1 |
| Compensated temp. range(deg C) : -10~+40 | Creep(%F.S/30min) : ±0.02 |
| Use temp. range(deg C) : -20~+60 | Zero balance(%F.S) : ±1.0 |
| Excitation voltage(V) : 9~12(DC) | Input resistance(Ω) : 405±10 |
| Safe overload (%F.S) : 120 | Output resistance(Ω) : 350±3 |
| Ultimate overload (%F.S) : 150 | Insulation resistance(MΩ) : ≥5000(100VDC) |
| Defend grade : IP65 |
|
Installation size (mm):
Rated Load(kg) | 50-200 | 250-500 | 750-2500 |
Recommended surface size(mm) | 600x600 | 600x600 | 1200x1200 |
A | 146 | 156 | 176 |
B | 75 | 95 | 125 |
C | 44 | 60 | 76.2 |
D | 50 | 70 | 95 |
E | 24 | 36 | 46 |
M | M12 | M12 | M16 |
Wiring schematic diagram:
Red: Input ( + ) White: Output ( - )
Black: Input ( - ) Green: Output ( + )
Notes:It used 4-core shielded cable(φ5×3000mm)
Load instruction: