Rated load(kg): 50-2500
Main features: The product is made of alloy aluminum. It is hermetically sealed with glue to IP65, surface anodized and anti-corrosion, integral structure and easy installation. The product is suit for electronic top scale, floor scale and other weighing equipment.
Parameters: |
Precision : C2 |
|
Temp. effect on span(%F.S/10deg C): ±0.02 |
Comprehensive error(%F.S) : ±0.02 |
|
Temp. effect on zero(%F.S/10deg C) : ±0.03 |
Rated output(mv/v) : 2.0±0.1 |
|
Compensated temp. range(deg C) : -10~+40 |
Creep(%F.S/30min) : ±0.02 |
|
Use temp. range(deg C) : -20~+60 |
Zero balance(%F.S) : ±1.0 |
|
Excitation voltage(V) : 9~12(DC) |
Input resistance(Ω) : 405±10 |
|
Safe overload (%F.S) : 120 |
Output resistance(Ω) : 350±3 |
|
Ultimate overload (%F.S) : 150 |
Insulation resistance(MΩ) : ≥5000(100VDC) |
|
Defend grade : IP65 |
|
Installation size (mm):
Rated Load(kg) |
50-200 |
250-500 |
750-2500 |
Recommended surface size(mm) |
600x600 |
600x600 |
1200x1200 |
A |
146 |
156 |
176 |
B |
75 |
95 |
125 |
C |
44 |
60 |
76.2 |
D |
50 |
70 |
95 |
E |
24 |
36 |
46 |
M |
M12 |
M12 |
M16 |
Wiring schematic diagram:
Red: Input ( + ) White: Output ( - )
Black: Input ( - ) Green: Output ( + )
Notes:It used 4-core shielded cable(φ5×3000mm)
Load instruction: