Rated load:500kg~5000kg
Main features:Alloy steel & stainless structure; bellows hermetically sealed by laser, nickel plated, waterproof and anti-corrosion, suitable for multiform environments; suitable for electronic platform scales, hopper scales, and other electronic weighing devies.
Parameters: |
Precison : C2 | | Temp. effect on span(%F.S/10ºC): ±0.017 |
Comprehensive error(%F.S) : ±0.03 | | Temp. effect on zero(%F.S/10ºC) : ±0.0123 |
Rated output(mv/v) : 2.0±0.003 | | Compensated temp. range(ºC ) : -10~+40 |
Creep(%F.S/30min) : ±0.024 | | Use temp. range(ºC ) : -20~+55 |
Zero balance(%F.S) : ±1.0 | | Excitation voltage(V) : 9~12(DC) |
Input resistance(Ω) : 350±5 | | Safe overload (%F.S) : 150 |
Output resistance(Ω) : 350±3 | | Ultimate overload (%F.S) : 200 |
Insulation resistance(MΩ) : ≥5000(100VDC) | | Defend grade : IP66 |
Installation size (mm):
Rated load(t) | A | B | C | D | E | M | d1 | d2 | |
0.5--2 | 130 | 31.8 | 15.8 | 25.4 | 76.2 | M12X1.75 | 13.5 | 13.5 | |
2.5--5 | 171.5 | 38.1 | 19.8 | 38.1 | 95.3 | M18X1.5 | 19.8 | 19.8 |
Wiring schematic diagram:
Red: Input ( + ) 111 White: Output ( - )
Black: Input ( - ) 111 Green: Output ( + )
Notes:It used 4-core shielded cable(φ5×10000mm)